Programming and Parameters
A055 [Relay Out Sel]
Sets the condition that changes the state of the output relay contacts.
Options 0 "Ready" (Not Faulted)
Default
1 "At Frequency"
2 "Motor Running"
3 "Reverse"
4 "Motor Overload"
5 "Ramp Regulated"
6 "Above Frequency"
7 "Above Current"
8 "Above DC Bus Volts"
9 "Retries Exhausted"
Related Parameter(s): P033, A056,
Relay changes state when power is applied. This indicates
that the drive is ready for operation. Relay returns drive to
shelf state when power is removed or a fault occurs.
Drive reaches commanded frequency.
Motor is receiving power from the drive.
Drive is commanded to run in reverse direction.
Motor overload condition exists.
Ramp regulator is modifying the programmed accel/decel
times to avoid an overcurrent or overvoltage fault from
occurring.
Drive exceeds the frequency (Hz) value set in A056
Out
Level].
Drive exceeds the current (% Amps) value set in A056
Out
Level].
Important: Value for A056
in percent of drive rated output current.
Drive exceeds the DC bus voltage value set in A056
Out
Level].
Value set in A092
[Auto Rstrt Tries]
[Relay Out Level]
must be entered
is exceeded.