Error Window; Starting Window - SICE A 948 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ROC Recall: (Recalls the data from the last ROC procedure performed.
Normally used when the data have to be recovered, without having to repeat the
ROC procedure, after a power failure while a job is in progress).
SYMBOL
Automatic master module search: (Opens the window for automatic
identification of the type of radio module connected to the central unit)
2.4 GHz module service: (Opens the window for control of central unit and
sensor radio modules operating at the frequency of 2.4 GHz)
When a communications error occurs (a sensor is switched off) or a measurement error occurs
(there is an obstacle between two sensors) the window in fig. 33 appears. The illustration show
the vehicle's two axles, with a line and an arrow identifying the sensor where the error has
occurred.
In these cases, the cause of the error must be corrected in order to resume normal operation.
If this is not possible, press F10 to return to the starting screen and correctly exit the program.
Then call in the technical support service.
When being used in demo mode without the sensors, the system must ignore measurement
and data transmission errors due to the absence of the sensors themselves.
To do this, select the "Demo" option in the Service" window.
To access the service window, press the F8 key from the programme's starting screen.
In this situation ("Demo" mode), a special icon is displayed in the top right-hand corner of the
heading bar. The values displayed are completely random.
At the end of the demo, remember to repeat the same procedure to return the machine to
working status.
The following keys are active in the starting window (fig. 26):
- F1
invokes on-line "Help".
- F2
exits the alignment program (with password prompt) and return to the Windows desktop.
- F3
(or "Enter") goes to the next screen in the established operation sequence (job record,
vehicle / customer databank, compensation, measurement).
- F4
sets up all the status option settings (setup).
- F6
to recover the last job done (with icon active).
- F8
opens the utility procedures window.
- F9
skips vehicle selection from the databank ("generic vehicle" mode).
- F10 exits the alignment program and Windows with the correct power-down procedure.
Press the F4 key to display/set up all the aligner options.
MENU AVAILABLE IN RADIO CONTROL STATUS

ERROR WINDOW

STARTING WINDOW

FUNCTION DESCRIPTION