7.6
Connecting the CRI/CRIN and piezo
CRI
WARNING – Risk of injury!
If the hydraulic connections for the testing
equipment and the injectors are not set up
properly, test oil can escape at high pres-
sure during the test or parts of the testing
equipment can burst. This can cause injury
or damage to property.
¶
Prior to switching on, check that all hose
assemblies have been properly connected
to the EPS 118 and the injector.
¶
Replace any leaking and defective hose
assemblies.
WARNING – Risk of hand injuries!
Uncontrolled closing of the protective hood
can lead to crushing or finger injury.
¶
Always close the protective hood using
the handle.
WARNING – Risk of burns from hot surfaces!
Contact with hot components and the hot
test equipment (e.g. injector) may cause
severe burns.
¶
Allow the components and test equipment
to cool down.
¶
Wear protective gloves.
DANGER – Risk of fatal injury from electro-
magnetic fields!
The high voltages at the piezo CRI (charging
of the actuators) and at the adapter cables
are a source of potential fatal injury for
persons wearing pace-makers are implanted
defibrillators.
¶
Piezo CRI testing may not be performed
by persons with pace-makers are implant-
ed defibrillators.
!
Do not check any damaged and/or severely corroded
components.
!
Use only for EPS 118 approved accessories. Using
accessories not intended for the EPS 118 can result
in incorrect measurements and thus a faulty evalua-
tion of the injector.
Robert Bosch GmbH
Operation | EPS 118 | 71
8
7
6
5
4
Fig. 31:
Schematic diagram of the CRI connection
1 Injected fuel quantity test connection
2 High-pressure connection
3 Test connection for return quantity (CRI/CRIN/piezo CRI)
4 Injection chamber
5 Injector
6 Adapter cable
7 Connection adapter for CRI/CRIN and piezo CRI
8 Connection cable 1 684 448 333
Only necessary for connecting non-Bosch CRI adapter cables.
1)
Included in accessory set 1 687 010 518 (non-Bosch CRI acces-
sory set).
i
For non-Bosch CRIs, accessory set 1 687 010 518 is
required (optional accessories).
i
The prerequisites to be observed when checking
and adjusting the Bosch piezo CRI can be found in
the test instructions for piezo CRI in ESI[tronic] 2.0.
These test instructions do not form part of the scope
of delivery. ESI[tronic] 2.0 can not be installed on the
EPS 118.
en
3
2
1
1)
|
1 689 989 220
2016-02-05