en
68 | EPS 118 | Commissioning
6.7.7
Display mode
i
The EPS 118 software 3 provides two different
methods (display mode) of testing the various injec-
tors, depending on the expertise of the user.
i
The mode names and passwords are case-sensitive.
Access data – display mode:
Overall test
mode
Password
basic
100
normal
102
expert
101
Procedure:
1. End the test.
2. In the start screen, select "Options >> Switch dis-
play mode", and confirm with <Yes>.
3. Enter the desired mode name and correct password,
and confirm with <Login>.
i
The login screen option "Remain logged in" provides
any easy way to reuse the same login details until
the next logout.
Description of the "basic" display mode
This display mode is intended for beginners. For each
injector, it provides a simple "Passed" or "Not passed"
test log (fig. 26).
i
The "basic" display mode is always used for access
by guests.
Fig. 26:
Report in " basic" display mode
|
1 689 989 220
2016-02-05
Good/bad indicator
Individual
Tendency
steps
X
–
–
X
X
–
X
X
X
Description of the "normal" display mode
This mode is intended for the normal operator. It pro-
vides a detailed test procedure with all of the test items
(fig. 27). For each test item, it provides a "Passed" or
"Not passed" test log (fig. 28).
Fig. 27:
Screen in "normal" display mode
Fig. 28:
Report in "normal" display mode