3.11.1 Water drain for tabletop ovens

The exhaust pipe can be conveyed to an open (grilled) floor drain (Fig.4); otherwise, between the drain pipe
of the appliance and the drain point with a "collection cup" (Fig. 5), there must be a height difference of
at least 30 cm in order to facilitate regular flow of water. In any case, the "air gap" (distance between the
drain pipe from the appliance and the open drain or the "collection vessel" of the drain duct pipe) must be
at least 25 mm.
Wall-mounted discharge is also allowed as long as the drain pipe maintains the steady slope of 4-5%.
Fig. 4

3.12 Steam drain

The appliance is equipped with a special metal pipe (DN30) for the discharge of steam from the cooking
chamber.
No other type of pipe can be connected to this pipe, which protrudes from the back of the casing.
Failure to comply with this specific prohibition shall relieve the Manufacturer from any liability concerning
the potential malfunction of the appliance and poor cooking quality.
Increasing the length of the original drain hose may result in the formation of abnormal "condensation" in
the cooking chamber.
To prevent steam from escaping from the exhaust pipe, place the appliance under the extractor hood, or
connect it to the extractor hood/condensing hood, specific for the appliance model used.

4. MAINTENANCE INSTRUCTIONS

A periodic check (at least once a year) of the appliance contributes to extending its service life and assures
proper operation.
Any maintenance operation on the appliance must only be done by highly qualified personnel trained in
the operations being performed and authorised. Operations must be carried out in accordance with the
safety regulations in force in the country where the appliance is installed, pursuant to the regulations
relative to plants and to workplace safety.
Before carrying out any maintenance on the appliance it must be disconnected from the mains and allowed
to cool down.
The Manufacturer is not responsible for any appliance faults caused by defective maintenance.

4.1 Access to the components for inspection

Removing the left side:
-
Magnetic door sensor (right opening)
-
Electronic components box
-
Cooking chamber probe
-
Terminal board 12V (accessory cable connection)
-
Contactors
-
Anti-interference filter (if any)
9
Fig. 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rc-711 eb1001195310011958

Tabla de contenido