Safety Thermal Device; Electronic Circuit Protection; Replacing The Cooking Chamber Gasket; Handle Closure Adjustment - Royal Catering RC-611 E Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Removing the back;
-
Tangential motor (on the back)
-
Circular resistors
-
Radial motors
-
Contactors
-
Power supply terminal board
-
Safety thermostat
-
Capacitors
-
Humidification solenoid valve
-
Humidification piping/fittings unit
Removing the right side:
-
Magnetic door sensor (left opening)
-
Peristaltic washing pump
-
Washing solenoid valve
-
Washing piping/fittings unit
Pulling the LED bar protection box (on the door):
-
LED Bar
-
Display

4.2 Safety thermal device

The appliance is equipped with a (manually reset) safety thermostat, to protect against excessive and
hazardous overheating which might accidentally occur inside it. If the safety thermostat trips, the power
supply to the appliance is cut off.
The safety thermostat is located at the back (bottom) of the appliance (see the attached "Technical Data
Sheet"); to reset it after it has tripped, unscrew the protective cap using an appropriate tool and press the
"reset" button all the way. Replace the protective cap so that it cannot be unscrewed without the use of a
tool.
Important
The safety thermostat should only be reactivated after eliminating the functional anomalies that caused it
to trip. This can only be done by a Service technician.

4.3 Electronic circuit protection

The electronic circuit of the microprocessor cards housed inside the "electronic component drawer" is
protected by fuses. If they "blow" they must be replaced with equivalent fuses with the same electrical and
dimensional characteristics.
Important
"Blown" fuses should only be replaced after eliminating the anomalies that caused them to blow. This can
only be done by a Service technician.

4.4 Replacing the cooking chamber gasket

The cooking chamber gasket has a rigid profile with retaining fins. This profile must be inserted in
the suitable perimeter seat on the "front" of the chamber.
To replace the gasket, simply remove the used one from its seat (pull tightly near the 4 corners)
and, after cleaning any impurities from the seat, insert the new gasket (to facilitate the assembly,
it is recommended to wet the profile of the gasket with soapy water).

4.5 Handle closure adjustment

Should the door handle not close properly, check and if required adjust the position of the "nose" (cross-
shaped) as follows:
10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rc-711 eb1001195310011958