Menu Control; Menu ¢Triggerpoint; Control Menu Screen Layout - Multiplex ROYALpro 7 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Menu Control

15.2.
Control
Parameter
Aileron
Trim
Elevator
Step
Rudder
D/R
Trvl
Expo
Collect.
P1 to P5
(Collective
Pitch)
Throttle
Min.
P1 to P5
Curve
Limit
Additional
menu points
Speed
Spoiler
Flap
Fixed values Flight phase specific
L. gear
Time
Tow rel.
No adjustment at the transmitter control end!
Brake
Adjustment is only possible in the menu
¤Servo, Calibrate
Gyro
Mixture
Direction of rotation
Centre
AUX1
End-points
AUX2
Curve points
Trigger
(
15.3.)
Point
Default
Current trim (display only)
Trim increment
0.5%
1.5%
2.5% 3.5%
Dual-Rate
10% to
100%
Transmitter control travel setting
Flight phase specific
0% to
100%
Flight phase specific
-100%
0%
100%
5-point curve, flight phase specific
Throttle idle (I.C. engine)
0%
20%
100%
0%: recommended
for electric
5-point curve, flight phase specific
Switch throttle curve on / off
ON
use throttle curve
OFF only a fixed value for electric
helicopters with regulated rotor
speed (Governor mode)
Slow function for throttle limiter
0.0s
to 6.0s
Slow function
0.0s
to 6.0s
-100%
OFF
100%
Slow function
0.0s
to 6.0s
á
P3
P1, P5
P2, P4
Menu ¢TriggerPoint
15.3.
In this menu you can set the switching thresholds for:
the stick
symbol ‡ ,
(left or right stick, according to mode) and
the two sliders E and F.
If a switching process is set up to operate with these
three transmitter controls, you can define a point
which determines when the switching is to take place:
Control
Parameter
# '
E
F
- *
Step
Example: switching a Timer at ¼ -throttle
Since the range extends from -100% to 100% , the
switching point for ¼ -throttle must be set at -50% .
Tip: using throttle / spoiler as switch
The sketch below clearly shows the connection bet-
ween the control position and the switching threshold.
For example, if the motor run time is to start at ¼ -
throttle, the threshold for the associated transmitter
control must be set to -50% .
Control position Switching point
100% (max.)
(¾)
50% (½)
¼
(
0% (OFF)
15.4.

Control menu screen layout

In our example we show the display for the transmitter
control Aileron with all the available set-up parame-
ters. However, the screen may not look exactly like
this, depending on the transmitter controls you have
assigned, and the parameters associated with them:
The screen is divided into three areas:
1. Transmitter control names, active flight phase
At the top is the name of the transmitter control (in
our example Aileron ). Next to this is the name of
the active flight phase (in our example the flight
phase NORMAL ).
Manual
Default
Idle position of the transmitter
control; display only, not defined
during the assignment process:
# back, ' forward
Current switched state:
- OFF, * ON
Trigger point:
-100%
0%
100%
+100%
0%
)
-100%
67

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Royalpro 9Royalpro 12

Tabla de contenido