PROFIdrive
PROFIdrive
• Slave address
receive/send
• Diagnostics
telegram
• Interconnection of the
free receive and send
telegrams
Telegram
E_STW1
370
E_ZSW1
[2447], [2457]
[2410], [2481], [2483]
Line supply voltage
monitoring
[8760]
<1> Only for S120 and G150.
1
2
DO: B_INF
Basic Infeed - Overview
Control words Status words
Sequence control
STW1
ZSW1
STW2
ZSW2
[8720], [8726]
[8732], [8738]
Thermal power module
Faults and alarms
monitoring
ϑ > ϑ
max
[8021]
[8060] ... [8075]
Gating signals, actual values
[8750]
3
4
Control Unit
Energize contactor
r0863.1
Closed-loop
To
control operation
SERVO/VECTOR
r0863.0
p0864
[2610]
Fxxxxx
!
Axxxxx
Vdc_act
r0070
5
6
fp_8710_54_eng.vsd
18.08.17 V05.02.03
<1>
Basic Infeed
U
V
W
1
1
1
Precharging
Vdc measurement
DCP
DCN
+
To the Motor Modules
7
8
Function diagram
- 8710 -
S120/S150/G130/G150
L1
L2
L3
PE