Descargar Imprimir esta página

Siemens SINAMICS S120 Manual De Listas página 2561

Ocultar thumbs Ver también para SINAMICS S120:

Publicidad

TM31 S_src DO 0
p4030
(0)
TM31 S_src DO 1
p4031
(0)
<1> Technical data:
Contact type:
Two-way contact
Maximum load current:
8 A
Maximum switching voltage:
250 V
Maximum switching capacity at 250 V
: 2000 VA (cos
AC
Maximum switching capacity at 250 V
: 750 VA (cos
AC
Maximum switching capacity at 30 V
:
240 W (resistive load)
DC
Required minimum current:
100 mA
Output delay:
20 ms
Overvoltage category:
Class II according to EN 61800-5-1
1
2
DO: TM31
Terminal Module 31 (TM31) - Digital relay outputs, electrically isolated (DO 0 ... DO 1)
p4048.0
0
1
1
p4048.1
0
1
1
, 30 V
AC
DC
= 1)
= 0.4)
3
4
r4047.1
r4047.1
NO: Normally Open contact ("open" in the quiescent state = NO contact)
NC: Normally Closed contact ("closed" in the quiescent state = NC contact)
5
6
fp_9556_51_eng.vsd
04.12.12 V05.02.03
p4099[0] (4000.00 µs)
X542
<1>
NC 0
1
COM
2
NO 0
3
<1>
NC 1
4
COM
5
NO 1
6
!
WARNING
Hazardous voltage!
These terminal can have
voltages up to 250 V AC!
7
8
Function diagram
- 9556 -
SINAMICS

Publicidad

loading

Este manual también es adecuado para:

Sinamics s150