F-DI assignment
Statically active
[2870.8]
F-DI 1
[2870.8]
F-DI 2
[2870.8]
SI ackn int evt P1
p10006 (0)
SI SLP ret F-DI P1
p10009 (0)
SI STO F-DI P1
p10022 (0)
SI SS1 F-DI P1
p10023 (0)
SI SS2 F-DI P1
p10024 (0)
SI SOS F-DI P1
p10025 (0)
SI SLS F-DI P1
p10026 (0)
SI SLS li0 F-DI P1
p10027 (0)
SI SLS li1 F-DI P1
p10028 (0)
SI SDI pos F-DI P1
p10030 (0)
SI SDI neg F-DI P1
p10031 (0)
SI SLS sel F-DI P1
p10032 (0)
SI SLP sel F-DI P1
p10033 (0)
1
2
DO: CU310-2
SI Extended Functions - CU310-2 control interface
De-select STO
[2819.1]
r9720.0
De-select SS1
[2819.1]
r9720.1
De-select SS2
[2819.1]
r9720.2
De-select SOS
[2819.1]
r9720.3
De-select SLS
[2820.1]
r9720.4
De-select SLP
[2822.1]
r9720.6
Acknowledgment
[2840.1]
r9720.7
Selection SLS bit 0
[2820.1]
r9720.9
Selection SLS bit 1
[2820.1]
r9720.10
De-select SDI positive
[2824.1]
r9720.12
De-select SDI negative
[2824.1]
r9720.13
Selected SLP
Put all
[2822.1]
r9720.19
outputs to 0
3
4
MM/CU
Extended Functions
[2819.8]
[2819.8]
[2819.8]
[2819.8]
[2820.8]
[2822.7]
[2840.8]
Safe motion
[2840.8]
monitoring in
the drives
[2840.8]
[2840.8]
[2824.8]
[2824.8]
[2823.8]
[2822.7]
[2840.8]
[2822.7]
[2822.7]
5
6
fp_2875_51_eng.vsd
07.11.12 V05.02.03
p9500 (12.00 ms)
STO active
r9722.0
SS1 active
r9722.1
SS2 active
r9722.2
SOS active
r9722.3
SLS active
r9722.4
Safely referenced
r9722.23
SLP savely active
&
SLP active
r9722.6
Internal event
r9722.7
SLS stage active bit 0
[2876.1]
r9722.9
[2877.1]
SLS stage active bit 1
r9722.10
SOS selected
r9722.11
SDI positive active
r9722.12
SDI negative active
r9722.13
SSM (n < limit)
r9722.15
SLP positioning range active
r9722.19
SP is valid
r9722.22
SLP upper limit maintained
r9722.30
SLP lower limit maintained
r9722.31
7
8
Function diagram
- 2875 -
SINAMICS