DRIVE-CLiQ socket 0
24 V DC
to the next
DRIVE-CLiQ socket 1
device
~
=
X524
M +
+24 V
+
+
M
M
M
M
X481
1
DI 0
2
DI 1
3
DI 2
4
DI 3
5
DO 0
6
DO 1
7
DO 2
8
DO 3
X482
10 V
1
AI 0+
2
AI 0-
3
AI 1+
4
AI 1-
5
AO 0+
V
6
AO 0-
7
V
AO 1+
8
AO 1-
AI: Analog Input
AO: Analog Output
DI: Digital Input
DO: Digital Output
1
2
DO: TB30
Terminal Board 30 (TB30) - Overview
1 = Simulation on
Simulation for DI 0 ... DI 3
p4095.0...3
0
1
r4022.0...3
1
Simulation signals
p4096.0...3
1
r4022.0
1
r4022.3
A
D
A
D
A
D
A
D
3
4
r4023.0...3
4 digital inputs, electrically isolated
r4023.0
r4023.3
[9100]
4 digital outputs, electrically isolated
p4030
p4033
[9102]
2 analog inputs +/-11 V
r4055[0]
[%]
r4055[1]
[%]
[9104]
2 analog outputs +/-11 V
p4071[0]
p4071[1]
[9106]
5
6
fp_9099_51_eng.vsd
12.03.13 V05.02.03
p4099 (4000.00 µs)
Reference quantities for 10 V or 100 %
p200x
10 V
100 %
p205x
10 V
100 %
7