Fixed setpoint selection, bit 0
Fixed setpoint selection, bit 1
Fixed setpoint selection, bit 2
Fixed setpoint selection, bit 3
Inhib neg dir
Inhib pos dir
Setpoint inversion
Motorized potentiometer, raise
Motorized potentiometer, lower
Bypass RFG
1
2
DO: SERVO, VECTOR, VECTOR3P, VECTORGL, VECTORM2C, VECTORSL
Internal control/status words - Control word, setpoint channel
Bit No.
p1020[C]
(0)
0
1 = Fixed setpoint, bit 0
p1021[C]
(0)
1
1 = Fixed setpoint, bit 1
p1022[C]
(0)
2
1 = Fixed setpoint, bit 2
p1023[C]
(0)
3
1 = Fixed setpoint, bit 3
4
Reserved
p1110[C]
(0)
5
1 = Inhibit negative direction
p1111[C]
(0)
6
1 = Inhibit positive direction
7
Reserved
8
Reserved
9
Reserved
10
Reserved
p1113[C]
(0)
11
1 = Setpoint inversion
12
Reserved
p1035[C]
(0)
13
1 = Motorized potentiometer, raise
p1036[C]
(0)
14
1 = Motorized potentiometer, lower
p1122[C]
(0)
15
1 = Bypass ramp-function generator
3
4
Control word, setpoint channel
5
6
fp_2505_51_eng.vsd
14.05.20 V05.02.03
p0115[3]
STW setpoint channel
r1198
r1198.0
r1198.1
r1198.2
r1198.3
r1198.5
r1198.6
r1198.11
r1198.13
r1198.14
r1198.15
7
8
Function diagram
- 2505 -
SINAMICS