Commissioning mode active (p0010 = 95)
Safety Integrated commissioning
p0010 = 95
SI password input
p10061
SI password new
p10062
SI ackn password
p10063
<1> The reference checksum must be equal to the actual checksum.
1
2
DO: TM54F_MA, TM54F_SL
SI TM54F - Parameter manager
Changing Safety parameters
r10054.0
Safety parameterization enable
=
x
y
SET
=
y = x
Disabling Safety functions
SI drv_obj assign_MA
p10010[0...5] = 0
SI drv_obj assign_SL
p10010[0...5] = 0
3
4
SI act CRC TM54F_MA
Activates all
&
password protected
safety parameters
SI act CRC TM54F_SL
Resetting safety parameters
All safety parameters
can be reset to the
&
factory settings via
p0970, p3900
5
fp_2891_51_eng.vsd
06.07.15 V05.02.03
p10000 (12.00 ms)
<1>
r10004
SI ref CRC TM54F_MA
p10005
=
&
Checksum check
for
Safety parameters
=
p10005
SI ref CRC TM54F_SL
r10004
<1>
p0010 ≠ 95
Quit Safety commissioning mode