Descargar Imprimir esta página

Siemens SINAMICS S120 Manual De Listas página 2558

Ocultar thumbs Ver también para SINAMICS S120:

Publicidad

24 V DC to the
X500
DRIVE-CLiQ socket 0
next device
~
X501
DRIVE-CLiQ socket 1
=
X524
M
+
+24 V
+
+
TM comp_no
p0151
M
M
M
M
X520
1
DI 0
2
DI 1
3
DI 2
4
DI 3
5
M1
6
M
[9550] 4 digital inputs, electrically isolated
X530
1
DI 4
2
DI 5
3
DI 6
4
DI 7
5
M2
6
M
[9552] 4 digital inputs, electrically isolated
X541
1
+
2
DI/D0 8
3
DI/D0 9
4
DI/D0 10
5
DI/D0 11
6
M
[9560], [9562] 4 digital inputs/outputs
X521
1
AI 0+
2
AI 0-
3
AI 1+
4
AI 1-
5
P10
6
M
7
N10
8
M
[9566], [9568] 2 analog inputs
1
2
DO: TM31
Terminal Module 31 (TM31) - Overview
1 = Simulation on
Simulation for DI 0...DI 11
p4095.0...11
r4021.0...11
0
1
Simulation signals
p4096.0...11
1
r4022.0
r4023.0
...
...
1
r4022.3
r4023.3
r4022.4
1
r4023.4
...
...
1
r4022.7
r4023.7
p4028.8
0
1
r4022.8
p4038
...
1
...
...
p4028.11
0
r4022.11
1
p4041
1
A
r4055[0]
[%]
D
A
r4055[1]
[%]
D
3
4
1
r4022.0...11
r4023.0...11
p4048.0
0
p4030
1
1
0
p4031
1
1
p4048.1
[9556] 2 digital outputs (relay)
p4071[0]
D
r4023.8
A
...
p4071[1]
D
...
A
r4023.11
[9572] 2 analog outputs
Alarm:
A35211
Overtemperature
sensor TM31
r4104.1
Fault:
F35207
Overtemperature
sensor TM31
[9576] Input for temperature sensor
5
6
fp_9549_51_eng.vsd
04.12.12 V05.02.03
p4099 (4000.00 µs)
X540
1
+24 V
2
+24 V
Auxiliary voltage for
3
+24 V
the digital inputs
4
+24 V
5
+24 V
6
+24 V
7
+24 V
8
+24 V
X542
1
NC 0
DO 0
2
COM
3
NO 0
4
NC 1
DO 1
5
COM
6
NO 1
X522
1
AO 0V+
2
AO 0-
3
AO 0A+
4
AO 1V+
5
AO 1-
6
AO 1A+
7
+Temp
8
-Temp
Temp KTY/PTC
r4105
D
A
7
Function diagram
SINAMICS
8
- 9549 -

Publicidad

loading

Este manual también es adecuado para:

Sinamics s150