n_act smooth signal
r2169
[8010.2]
n_set for msg
<5>
p2151[C]
<7>
r1170
[3080.8]
n_set for msg
p2151[C]
r1438
<6>
[5042.5], [5210.4]
+
–
n_act 2
+
p2154[C]
0
<1> Applies only if the function module "extended
signals/monitoring functions" is active (r0108.17 = 1).
<2> VECTOR: Calculated.
<3> VECTOR: Depending on the drive unit (1000 or 1600 µs).
<4> Evaluation only for:
Pulse enable and operating enable (r0899.2)
or OFF1
or OFF3
or rotating measurements
or friction characteristic plot.
<5> Only for VECTOR.
<6> Only for SINAMICS S120 and SERVO.
<7> The value is displayed correctly only with r0899.2 = 1
(Operation enabled).
1
2
DO: SERVO, VECTOR
Signals and monitoring functions - Speed signals 2
0
<2>
n_hysteresis 3
0.00...300.00 [rpm]
p2150[D] (2.00)
n_thresh val 4
0.00...210.000 [rpm]
p2163[D] (90.00)
Torque control active
0
r1407.2
[6060.3]
<2>
n_hysteresis 4
0.00...200.00 [rpm]
p2164[D] (2.00)
RFG active
p2148[C]
(0)
3
4
<1>
0
n_hysteresis 3
0.00...300.00 [rpm]
p2150[D] (2.00)
<2>
t_del_off n_i=n_se
0.0...500.0 [ms]
p2166[D] (200.0)
Speed setpoint actual value deviation in tolerance t_off
0
T
≥1
1
1
0
0
t_on n_act=n_set
0.0...10 000.0 [ms]
p2167[D] (200.0)
Enable alarm A07903
p2149.0[D]
Speed setpoint actual value deviation in tolerance t_on
T
0
1 = RESET
5
6
fp_8011_54_eng.vsd
11.04.12 V05.02.03
p0115[3] (4000.00 µs)
p0115[3] (<3>)
n_act ≥ 0
r2197.3
[2534.3]
n_set > 0
r2198.5
[2536.3]
n_thresh val 3
0.00...210000.00 [rpm]
p2161[D] (5.00)
|n_set| < p2161
r2198.4
[2536.3]
0
n_hysteresis 3
0.00...300.00 [rpm]
p2150[D] (2.00)
r2197.7
[2534.3]
<5>
<4>
A07903 is only signaled for p2149.0 = 1 and r2197.7 = 0.
r2199.4
[2537.3]
Ramp-up/ramp-down completed
SET
Q
r2199.5
[2537.3]
(Q=1)
Priority
RESET
1 RESET
Q
(Q=0)
2 SET
7
8
Function diagram
- 8011 -
S120/S150/G130/G150