Signal targets for STW2 in Interface Mode SIMODRIVE 611 universal (p2038 = 1)
Signal
Meaning
STW2.0
Drive data set selection DDS, bit 0
STW2.1
Drive data set selection DDS, bit 1
STW2.2
Drive data set selection DDS, bit 2
STW2.3
Reserved
STW2.4
1 = Bypass ramp-function generator
STW2.5
Reserved
STW2.6
1 = Integrator inhibit, speed controller
STW2.7
1 = Parking axis selection
STW2.8
1 = Traverse to fixed endstop
STW2.9
Drive data set selection DDS, bit 3
STW2.10
Drive data set selection DDS, bit 4
STW2.11
= Motor changeover, feedback signal
STW2.12
Master sign-of-life, bit 0
STW2.13
Master sign-of-life, bit 1
STW2.14
Master sign-of-life, bit 2
STW2.15
Master sign-of-life, bit 3
<1> Used in telegrams 102, 103, 105, 106, 116, 118, 125, 126, 136, 138, 139, 146, 148, 149, 166.
<2> For a 1 signal, the integral component of the speed controller is cleared and the integrator is inhibited.
1
2
DO: SERVO
PROFIdrive - STW2 control word interconnection (p2038 = 1)
Interconnection
parameters
p0820[0] = r2093.0
p0821[0] = r2093.1
p0822[0] = r2093.2
p1122[0] = r2093.4
<3>
<2>
p1477[0] = r2093.6
p0897 = r2093.7
p1545[0] = r2093.8
p0823[0] = r2093.9
p0824[0] = r2093.10
p0828[0] = r2093.11
p2045 = r2050[3]
<3> Only if the function module "extended setpoint channel" is active (r0108.8 = 1).
3
4
[Function diagram]
[Function diagram]
internal control word
signal target
-
[8565]
-
[8565]
-
[8565]
-
-
-
-
[3060] [3070]
-
-
-
-
[5040] [5210]
-
-
[2520.2]
[8012]
-
[8565]
-
[8565]
-
-
-
[2410]
5
6
fp_2445_55_eng.vsd
17.07.13 V05.02.03
PROFIdrive sampling time
<1>
Inverted
-
-
-
-
-
-
-
-
-
-
-
-
-
7
8
Function diagram
- 2445 -
SINAMICS S120/S150