Signal targets for POS_STW1 (positioning mode, r0108.4 = 1)
Signal
Meaning
POS_STW1.0
Traversing block selection, bit 0
POS_STW1.1
Traversing block selection, bit 1
POS_STW1.2
Traversing block selection, bit 2
POS_STW1.3
Traversing block selection, bit 3
POS_STW1.4
Traversing block selection, bit 4
POS_STW1.5
Traversing block selection, bit 5
POS_STW1.6
Reserved
POS_STW1.7
Reserved
1 = Absolute positioning is selected.
POS_STW1.8
0 = Relative positioning is selected.
POS_STW1.9
1 = Absolute positioning/MDI direction selection, positive.
2 = Absolute positioning/MDI direction selection, negative.
3 = Absolute positioning through the shortest distance.
POS_STW1.10
0 = Absolute positioning through the shortest distance.
POS_STW1.11
Reserved
1 = Continuous transfer
POS_STW1.12
0 = Activate MDI block change with
POS_STW1.13
Reserved
1 = Signal setting-up selected
POS_STW1.14
0 = Signal positioning selected.
POS_STW1.15
1 = MDI selection
<1> Used in telegram 111.
1
2
DO: SERVO, VECTOR
PROFIdrive - POS_STW1 positioning control word 1 interconnection (r0108.4 = 1)
of a traversing task (STW1.6)
3
4
Interconnection
[Function diagram]
[Function diagram]
parameters
internal control word
signal target
p2625 = r2091.0
-
p2626 = r2091.1
-
p2627 = r2091.2
-
p2628 = r2091.3
-
p2629 = r2091.4
-
p2630 = r2091.5
-
-
-
-
-
p2648 = r2091.8
-
p2651 = r2091.9
-
p2652 = r2091.10
-
-
-
p2649 = r2091.12
-
-
-
p2653 = r2091.14
-
p2647 = r2091.15
-
5
6
fp_2463_55_eng.vsd
17.07.13 V05.02.03
PROFIdrive sampling time
<1>
Inverted
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7
8
Function diagram
- 2463 -
SINAMICS S120/S150