Mode Related Settings - RADWAG 4Y Serie Manual Del Usuario

Ultaramicrobalanza. microbalanza. microbalanzas para pipetas. microbalanzas para los filtros. balanzas analíticas. balanzas analíticas para los filtros
Ocultar thumbs Ver también para 4Y Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

[T2-] error value
[T1-] error value
[T1+] error value
[T2+] error value
[T3+] error value
[T4+] error value
Disqualifying quantity of
samples [Qn-T4]
Disqualifying quantity of
samples [Qn-T3]
Disqualifying quantity of
samples [Qn-T2]
Disqualifying quantity of
samples [Qn-T1]
Disqualifying quantity of
samples [Qn+T1]
Disqualifying quantity of
samples [Qn+T2]
Disqualifying quantity of
samples [Qn+T3]
Disqualifying quantity of
samples [Qn+T4]
Caution! For information on how to edit product records read section 30.2 of this user manual.
4. Return to <
SQC> mode home screen, press
bar,
5. <Batch Number> window with an on-screen keyboard opens (only if <Request batch number>
parameter is set to <YES> parameter),
6. Enter the number of controlled product batch, press
Caution!
You can abort the control process at any time, to do it press
bottom bar.
In the course of control other on-screen keys and function keys,

26.2. Mode Related Settings

The supplementary settings enable you to adjust the working mode to your needs and requirements.
SQC mode settings:
Request batch number: use this function to force the user to enter batch number of a
product prior each control procedure start.
Procedure:
1. Select <Request batch number> parameter, window with NO/YES value is displayed.
Select <No> – option disabled, or <Yes> – option enabled.
Max permissible negative T2 error value with nominal
weight value as point of reference.
Max permissible negative T1 error value with nominal
weight value as point of reference.
Max permissible positive T1 error value with nominal
weight value as point of reference.
Max permissible positive T2 error value with nominal
weight value as point of reference.
Max permissible positive T3 error value with nominal
weight value as point of reference.
Max permissible positive T4 error value with nominal
weight value as point of reference.
Max permissible quantity of T4 low limit errors with
nominal weight as point of reference.
Max permissible quantity of T3 low limit errors with
nominal weight as point of reference.
Max permissible quantity of T2 low limit errors with
nominal weight as point of reference.
Max permissible quantity of T1 low limit errors with
nominal weight as point of reference.
Max permissible quantity of T1 high limit errors with
nominal weight as point of reference.
Max permissible quantity of T2 high limit errors with
nominal weight as point of reference.
Max permissible quantity of T3 high limit errors with
nominal weight as point of reference.
Max permissible quantity of T4 high limit errors with
nominal weight as point of reference.
button (control start) located in the bottom
button to confirm.
- 118 -
button (control stop) located in the
and
keys are locked.