Assembly
Table 8:
Assignment of the X10 (POWER) plug, M12,
A-coded CANopen sb
Pin
X10
Assignment
1
UL
Not used
2
U
Valve power supply
Q1
3
OV
Ground for U
4
U
Valve power supply
Q2
1)
Both supply voltages (pin 2, pin 4) must be protected by an
external fuse (3 A, F).
Table 9:
Power consumption on X10 (POWER) on
bus coupler
Signal
Assignment
UL
Logic inputs
U
Valves
Q1
U
Valves
Q2
Dangerous voltages
A power pack without safe isolation may lead to
dangerous voltages in the case of a fault. This may
damage the system and cause injuries arising from
electric shock.
O
Only use a power pack with safe isolation
according to EN60747, VDE 0551 classification! The
corresponding electrical circuits are thus SELV/
PELV circuits in accordance with IEC 60364-4-41.
1)
U
and U
L,
Q1
Q2
1)
Total current
Max. 0.5 A
Max. 3 A
Max. 3 A
CAUTION