To activate the updated Database, perform the ACTI-
VATE TPMS VERSION procedure described previously.
RESET TPMS
43
1. To reset the TPMS if necessary, select RESET TPMS
then press the confi rm button
(Fig. 43).
REINITIALISE TPMS
1. To reinitialise the TPMS if necessary, select RESET
44
TPMS then press the confi rm button
(Fig. 44).
5.9.i. Touch screen calibration
1. Select TOUCH SCREEN CALIBRATION then press
45
the confi rm button
(Fig. 45).
CAUTION!
For greater precision, wear gloves when carrying out calibration.
UK
2. Touch the 5 crosses displayed on the touch
screen in sequence with your fi nger (Fig. 45a). Do
not use a pointed object such as a pencil to touch
the screen, as this may cause miscalibration.
3. After calibrating, touch the display with your
45a
fi nger (Fig.45b) and check that the pointer follows
the movements of your fi nger. Otherwise, repeat
the procedure.
4. Select one of the following:
- SAVE to save calibration
- CANCEL to exit calibration without saving
- RESTART CALIBRATION to repeat the procedure.
45b
User manual S 1000
173