Yellow at limit of permissible temperature range. It is not advisable to carry out operations
according to the WDK procedure. Temperature range 15 - 19 °C and 26 - 30 °C
Red tyre temperature not within permissible range. It is not possible to carry out operations
according to the WDK procedure. Temperature < 15°C or > 30°C. Bring the temperature of
the tyre within the permissible range.
- Press the
button (see Fig. 54c) to exit the TEMPERATURE SENSOR function and
return to the main screen.
TROUBLESHOOTING
The sensor does not read correctly
Sensor connector disconnected or not connected
properly
- Connect the connector correctly
(see Fig. 54d).
Sensor or read circuit failure
- If the problem persists, contact the technical
54d
assistance.
6.5 TPMS
From the main screen (Fig. 55), press the
button.
The TPMS is an electronic device to read pressure
sensors and check their operation, directly on the
55
tyre changer. Specifi cally, the operator can:
- Check sensor integrity and operation before car-
UK
rying out any operation on tyres
- Check that the sensors conveys the correct pressure and temperature values
- Check sensor battery status
- Acquire information on mounting and the torque values of the valves
- Acquire the spare part codes of valves
- Check integrity and operation after carrying operations on tyres
- Update the vehicle/valve database from the company site via USB
Intended operating conditions
The TMPS has been designed exclusively to diagnose the correct operation of pressure
sensor valves, as described in this manual. Any other use is inappropriate.
Technical data
- Power supply.........................12V dc
User manual S 1000