shown in Fig. 46e is displayed.
9. Lift the demounting tool.
10. Switch the machine off, then on again.
NEVER press x-axis calibration during the work phases but only during the calibra-
tion phase with the template mounted!
5.9.m Calibrating the Y axis
This operation must only be carried out by author-
ised personnel.
PROCEDURE:
Access the SERVICE menu and select Y AXIS CALI-
BRATION (Fig. 47)
Follow the procedure indicated on the machine display.
- bring both carriages fully up, then press PLAY (Fig.47a)
- bring both carriages fully down, then press PLAY (Fig.47b)
At the end of the procedure, remember to switch the ma-
chine off and then back on again.
5.9.n. P3K DIagnostics
1. Select P3K DIAGNOSTICS then press the confi rm
button
(Fig. 48).
2. At the end, Fig. 48a will be displayed.
If error messages are displayed, check the mes-
sages in the ERROR MESSAGES chapter in this
manual.