Descargar Imprimir esta página

SICE S 1000 Manual De Instrucciones página 192

Ocultar thumbs Ver también para S 1000:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

- Make sure the condensation is draining from
the fi lter-regulator unit:
The regulating fi lter unit is equipped with a semi-
automatic device to drain the condensate. This
device is automatically activated whenever pneu-
matic supply to the machine is cut off. Drain the
condensate manually (1, Fig. 56b) when the level
rises above level 2, Fig. 56b.
To carry out every month
- Clean and lubricate the upper and lower trolley
guide (Fig. 56c):
Clean with environmentally-friendly solvents and
lubricate with LIPLEX EP 2 lubricant or equivalent.
To carry out every two months.
- Check operation of the stop button (Fig. 56d):
If operating properly, the stop button will appear
on the display.
Otherwise, contact technical assistance.
To carry out every two months.
- Contact the service network to check the belts
and rubber pads:
Periodic check by the service network.
To carry out every 7000 wheels
- General machine check, contact the service net-
work:
General periodic check by the service network.
To carry out every year