Connection And Positioning Of The Product Detector - Weber Legi-Air 2050 Traduccion De Las Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 343
Chapter 6 Installation and initial commissioning

Connection and positioning of the Product Detector

DE
GB
An M18 photocell is delivered including a reflector, in order to trigger a labelling operation.
The 25-pin photocell connector can be attached directly to the signal interface on the con-
trol panel of the applicator control.
The attachment of the sensor and the reflector must still allow subsequent position
changes. To avoid unwanted reflections, a slanted arrangement of sensor and reflector is
of advantage:
Version: 24.05.2016
Use only original sensors.
̶ The connection of sensors which are not included in the
scope of delivery, requires an expert knowledge and may only
be performed by qualified personnel.
MODE
GND
24 VCD
TRIGGER
No.
Designation
1
UNWANTED REFLECTION IS NOT DETECTED BY THE SENSOR
2
REFLECTOR
3
REFLECTED LIGHT BEAM
4
PRODUCT
5
CONVEYOR ROUTE
6
SENSOR (LIGHT BARRIER)
SENSOR
Page 44 of 68
40037053 BTA Legi-Air 2050
Fig. 6-6: Light barrier and wiring diagram
Fig. 6-7: Light barrier arrangement
ML-GB

Publicidad

Tabla de contenido
loading

Tabla de contenido