Descargar Imprimir esta página

Charging System - Yamaha WR450F 2003 Manual De Servicio Del Propietario

Publicidad

EC680000

CHARGING SYSTEM

EC681001
INSPECTION STEPS
If the battery is not charged, use the following inspection steps.
*1 Check fuse.
OK
*2 Check battery.
OK
Check each coupler and
wire connection.
OK
Check charging voltage.
No good
Check AC magneto.
OK
Replace rectifier/regulator.
*1 marked: Refer to "FUSE INSPECTION" section in the CHAPTER 3.
*2 marked: Refer to "BATTERY INSPECTION AND CHARGING" section in the CHAPTER 3.
NOTE:
Remove the following parts before inspection.
G
1) Seat
2) Fuel tank
Use the following special tool in this inspection.
G
Pocket tester:
YU-3112-C/90890-03112
All manuals and user guides at all-guides.com
CHARGING SYSTEM
No good
No good
No good
Charging coil
6 - 17
OK
No good
+
ELEC
Replace fuse and
check wire harness.
Recharge or replace.
Repair or replace.
Charging system is
good.
Replace.

Publicidad

Capítulos

loading