PDH Tabs
E0/64K RX
Payload Content
Note: Payload content configuration is only available for decoupled test mode,
otherwise the payload content is coupled with the E0/64K TX configuration.
Select the payload content by pressing once or several times on each
timeslot until the desired content appears (or use the Set All buttons).
Choices are None and Pattern. The default setting is Pattern.
Pattern: Uses the pattern from the received signal.
None: Does not use the pattern.
Set All: Allows to set the payload content of all timeslots with (Pattern)
or without (None) the selected Pattern.
374