Overwrite: Available with OTN Intrusive through mode only
(optional). The Overwrite check box when selected, generates the
defined Payload Type.
Code allows entering the code of the payload type. Choices are
00 to FF.
Binary allows either displaying the payload code value in binary
(when enabled) or hexadecimal (when disabled). This setting is
disabled by default.
Alarm Generation
Note: Alarm generation is only available with multiplexed test case only.
OPU-MSIM (Multiplex Structure Identifier Mismatch): OPU-MSIM is an
OPU alarm that is available for multiplexed test case only. The
OPU-MSIM alarm is generated by corrupting the content of the PSI
(bytes 2 and 3 for ODU0 in ODU1, bytes 2 to 5 for ODU1 in ODU2, and
bytes 2 to 17 for ODU2 in ODU3).
Note: OPU-AIS and OPU-CSF are only available on the OPU client signal
(designated as LO in the standard). In this case, OPU-MSIM is not available.
OPU-AIS (OPU - Alarm Indication Signal): The OPU-AIS alarm is
generated by generating the PRBS 2^11-1 pattern.
OPU-CSF (OPU - Client Signal Fail): The OPU-CSF alarm is generated
by setting the bit 1 of the OPUk PSI[2] byte to "1".
On/Off button: The On/Off button is used to activate/deactivate the
selected alarm. This setting is disabled (Off) by default.