EXFO FTB-8510B Guia Del Usuario página 962

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SDH Tabs
Regenerator Section RX (SDH)
J0 Trace
Received Message: Displays the J0 value in 16 or 64 bytes format. The
<crc7> represents the CRC-7 for a 16-bytes format. The last two bytes
of a 64-bytes format, <C
carriage return and a line feed.
Enable RS-TIM (Regenerator Section - Trace Identifier Mismatch):
Enables the Trace Identifier Mismatch for the expected message
defined when the Enable RS-TIM check box is selected. The Enable
RS-TIM check box has to be selected to give access to the expected
trace format and message. When the Enable RS-TIM check box is
selected, the J0 1-byte is available from the Regenerator Section OH
TX/RX (SDH) on page 313.
Expected Message: Allows entering the message that is expected.
J0 value should be ASCII suitable characters. The default message is
EXFO SONET/SDH for 16 bytes and EXFO SONET/SDH Analyzer
Section/RS trace test message for 64 bytes.
Expected Format: Allows the selection of the format expected.
Choices are 16 or 64 bytes. The default setting is 16 bytes.
312
> and <L
>, represent respectively a
R