EXFO FTB-8510B Guia Del Usuario página 776

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Summary Tabs
Test Summary
Test Status
Start Time: Indicates the date and time the test has been started. The
date and time reset every time the test is restarted. The default time
format is ISO (yyyy-mm-dd hh:mm:ss) unless otherwise set from the
Application Preferences on page 528.
Link: Indicates the status of the 10G Ethernet RX signal. Only available
with OTU1e/OTU2e interface when 10G Ethernet is selected.
Test Configuration
Test Name: The name of the test connection is used to identify the test.
A maximum of 8 characters are allowed. The default setting is TEST.
Test Mode: Indicates the selected test mode.
126
Normal: Indicates that the unit is monitoring a signal in
coupled/decoupled and/or through mode.
Dual RX: Indicates that the FTB-8105/15/20/30 unit is monitoring
two DS1 or DS3 signals at the same time. Both RX ports are
coupled at the exception of the termination mode. Dual RX is not
available then the AUX connector is used for synchronization (refer
to Clock Synchronization on page 520 for more information).
FTB-8100 Series Transport Blazer

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ftb-8510gFtb-8525Ftb-8535Ftb-8120nceFtb-8103nce

Tabla de contenido