The following section overhead byte values are displayed in hexadecimal
format. However, a common field allows to see the value of specific byte in
binary format. Click on the blue label of a byte and its binary value will be
displayed in the common field beside the Timeslot selection.
J1: Trace. J1 is only available when Enable Trace from the HOP TX
(SDH) on page 335 is disabled.
B3: BIP-8. This byte is not programmable from the HOP OH TX tab.
C2: Path Signal Label. Entering a C2 byte will automatically update the
Path Signal Label (C2) selection and vice versa.
G1: Path Status
F2: User Channel
H4: Multiframe Indicator. This byte is not programmable with LOP or
VCAT.
F3: User Channel
K3: Automatic Protection Switching (APS)
N1: (Network operator byte) Tandem Connection Monitoring (TCM)
SONET/SDH Application
SDH Tabs
HOP OH TX/RX (SDH)