EXFO FTB-8510B Guia Del Usuario página 758

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Creating and Starting a Test Case
Typical Test Cases
Creating an OTN Overclocked
(OTU1e/OTU2e/OTU1f/OTU2f) Test Case (FTB-8130,
FTB-8130NG, and FTB-8130NGE)
To create an OTN overclocked test on an FTB-8130, FTB-8130NG, or
FTB-8130NGE module:
1. Test configuration:
1a. Select the source Clock Mode that will be used
1b. Select Normal as the Test Mode. Refer to Test
1c. Make sure the Coupled check box is selected.
1d. Select the Through check box to loop the RX signal to the TX port.
1e. Select the OTN Intrusive check box to loop the RX signal to the
1f. Leave the SONET/SDH Intrusive check box cleared.
1g. Press Next.
108
for the test. Refer to Clock Configuration on
page 129 for more information.
Configuration on page 126 for more
information.
The Clock Mode is automatically set to Recovered when the
Through check box is selected.
TX port with TX overwrite capabilities.
FTB-8100 Series Transport Blazer

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ftb-8510gFtb-8525Ftb-8535Ftb-8120nceFtb-8103nce

Tabla de contenido