Creating an Optical SONET/SDH Test Case
(FTB-8115/20/30)
The following procedure describes a normal optical SONET/SDH the test
case on the FTB-8115/20/30 modules.
For Next generation test case, see Creating a Next Generation Test Case
including VCAT/LCAS and GFP on page 103.
For FTB-8140, see Creating an Optical SONET/SDH Test Case on an
FTB-8140 on page 87.
To create an Optical SONET/SDH Test on an FTB-8115/20/30
module:
1. Test configuration:
1a. Select the source Clock Mode that will be used
1b. Select Normal as the Test Mode. Refer to Test
1c. Select the Coupled check box to set the same
1d. Select the Through check box to loop the RX signal to the TX port.
1e. Select the SONET/SDH Intrusive check box to loop the RX signal
1f. Leave the OTN Intrusive check box cleared. OTN Intrusive is not
1g. Press Next.
SONET/SDH Application
for the test. Refer to Clock Configuration on
page 129 for more information.
Configuration on page 126 for more information.
settings for both the TX and RX signals or clear
the Coupled check box to configure the TX and RX signal
individually (decoupled).
The Clock Mode is automatically set to Recovered when the
Through check box is selected.
to the TX port with TX overwrite capabilities. SONET/SDH
Intrusive is not available on FTB-8115.
available on FTB-8115.
Creating and Starting a Test Case
Typical Test Cases
83