WEG CLIC-02 Manual Del Usuario página 140

Microcontrolador programable
Ocultar thumbs Ver también para CLIC-02:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Hardware Specification
Mode
Power Supply
8ER-A
8ER-D
8ET-D
4AI
4PT
2AO
* Maximum number of digital inputs, seeing that the analog inputs are set to work as digital
inputs.
Existing feature
9.2 VOLTAGE SPECIFICATIONS
Content
CLIC-02/10HR-A CLIC-02/20HR-A
Operating
100-240 Vac
Voltage
Voltage
85-265 Vac
variation
Operating
50 / 60 Hz
Frequency
Frequency
variation
Maximum time
10 ms (half
allowed with no
cycle) / 20 times
supply
(IEC61131-2)
Fuse
Required to
connect a fuse or
a circuit breaker
Insulation
110 Vac 220 Vac 110 Vac 220 Vac
Average current
90 mA
consumption
110 Vac 220 Vac 110 Vac 220 Vac
85 mA
Voltage
consumption
140 | CLIC-02
4
4
relay
4
4
relay
4
4
transistor
4*
4*
2
analog
100-240 Vac
85-265 Vac
50 / 60 Hz
47-63 Hz
47-63 Hz
10 ms (half
cycle) / 20 times
(IEC61131-2)
Required to
connect a fuse or
a circuit breaker
of 1A
None
90 mA
100 mA 100 mA
Todas as entradas e relés Desligados
85 mA
90 mA
7.5 W
12.5 W
- English -
4
4
CLIC-02/20HR-D
CLIC-02/20HT-D
24 Vdc
20.4-28.8 Vdc
10 ms / 10 times
(IEC61131-2)
Required to
connect a fuse or
a circuit breaker
of 1A
of 1A
None
None
All inputs and relays on
24 Vdc 28,8 Vdc 24 Vdc 28,8 Vdc
145 mA
24 Vdc 28,8 Vdc 24 Vdc 28,8 Vdc
90 mA
80 mA
5 W
CLIC-02/12HR-D
CLIC-02/12HT-D
24 Vdc
20.4-28.8 Vdc
10 ms / 10 times
(IEC61131-2)
Required to
connect a fuse or
a circuit breaker
of 1A
None
185 mA
115 mA
125 mA
120 mA
75 mA
85 mA
4.5W

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido