Application Examples
13.2.2 Solução Tradicional
Reference Circuit
L
B1
MC3
N
Open Door
When any B1 or B2 sensors detect the presence of a visitor, the door will be open. After
a certain time without detecting anyone, MC4 relay will operate the door lock command.
13.2.3 Using CLIC as a system controller
The use of CLIC as a system controller can simplify the circuit. All you need to do is to
connect the presence sensors, limit switches and timer to CLIC.
Used components:
MC1 door opening contactor
„
MC2 door closing contactor
„
S1 (NF contact) closing limit switch
„
S2 (NF contact) opening limit switch
„
B1 (NA contact) external infrared sensor
„
B2 (NA contact) internal infrared sensor
„
202 | CLIC-02
B2
MC3
MC2
MC4
S2
MC2
MC1
- English -
MC3
MC3
S1
MC1
MC4
MC2
Open
Closed
S2
B1
B2
Waiting
Time