WEG CLIC-02 Manual Del Usuario página 202

Microcontrolador programable
Ocultar thumbs Ver también para CLIC-02:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Application Examples
13.2.2 Solução Tradicional
Reference Circuit
L
B1
MC3
N
Open Door
When any B1 or B2 sensors detect the presence of a visitor, the door will be open. After
a certain time without detecting anyone, MC4 relay will operate the door lock command.
13.2.3 Using CLIC as a system controller
The use of CLIC as a system controller can simplify the circuit. All you need to do is to
connect the presence sensors, limit switches and timer to CLIC.
Used components:
MC1 door opening contactor
MC2 door closing contactor
S1 (NF contact) closing limit switch
S2 (NF contact) opening limit switch
B1 (NA contact) external infrared sensor
B2 (NA contact) internal infrared sensor
202 | CLIC-02
B2
MC3
MC2
MC4
S2
MC2
MC1
- English -
MC3
MC3
S1
MC1
MC4
MC2
Open
Closed
S2
B1
B2
Waiting
Time