WEG CLIC-02 Manual Del Usuario página 78

Microcontrolador programable
Ocultar thumbs Ver también para CLIC-02:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Ladder Logic Programming
7.4.1.4 Timer Mode 3 – De-energizing Delay
The timer will start the output contacts immediately after its enabling, but when this enabling
is turned off, the timer output will remain active during the programmed time. When the
reset input is activated, the current counting value is reset and the timer outputs will be
turned off.
In example 1, the timer will count 5 seconds after having its enabling sign turned off. In
example 2, we observe the acting of the reset input, which resets the counting value and
disables the timer output. Every time the timer is counting to turn off and the enabling input
is turned on again, the current counting value will be reset.
Entrada de habilitação
Timer enabling input
do temporizador
Saída do temporizador
Timer output
(T01 ~T1F)
Entrada de reset
Reset input
Entrada de habilitação
Timer enabling input
do temporizador
Saída do temporizador
Timer output
(T01 ~T1F)
Reset input
Entrada de reset
78 | CLIC-02
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
- English -
ON
ON
OFF
ON
OFF
ON
ON
t = programmed time value
t = valor de tempo programado
OFF
OFF
ON
OFF
OFF

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido