Screen Configuration - WEG CLIC-02 Manual Del Usuario

Microcontrolador programable
Ocultar thumbs Ver también para CLIC-02:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Programming Tool

5.5.8.1 Screen Configuration:

2
1
7
6
5
3
4
Displays only variables
used in the program
 First, we insert the Hxx coil and select mode 1 - display.
 Through the configuration pop-up "HMI/Text", we Edit the Hxx message to be displayed
 Selecting letter "T", we insert this character on the screen, as the cursor position
 Selecting letter "E", we keep inserting the characters as shown above
 We select "T01 Current" to display the current counting value of the timer T01
 We select "T01 Current (unit)" to display the value of T01, containing the counting unit
(seconds)
 Selecting "T01 Adjustment (unit)", we enable a Field where the user may modify the
pre-selected value of T01, when the screen H01 is shown.