Working Using Usb - Orbitalum ORBIMAT 300 SW Traduccion Del Manual De Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 309
ORBIMAT 300 SW
Abb. 23:
Process details
4. Highlight the input field, enter the text and save.
8.10.3

Working using USB

Supported storage media:
USB storage media
X Ensure that the memory card has "FAT formatting".
Available functions:
Saving and reading procedures.
Backing up, restoring and updating system data. These system data are essentially the operating software itself,
the library of the available weld heads, the auto programming database and the various operating languages of the
software.
A USB stick symbol is displayed in the bottom right-hand corner of the display.
The USB stick symbol is not displayed?
X Remove the USB medium and insert it again. The USB stick recognition can take up to 30 seconds.
Activating logs for a weld process
D Connect the USB medium.
1. In the main menu, press softkey 1 "Weld" or softkey 2 "Test".
2. Select the "Yes" option in the Save log files" field.
During the welding process, the logs are saved on the external memory card.
If an external memory card is not inserted, an error message appears at the end of the welding process.
To always activate saving of the logs for a procedure:
X Save the procedure with activated option.
(14.01.21) OW_ORBIMAT_300SW_BA _852060202_00_EN
Abb. 24:
Comments
ORBITALUM TOOLS GMBH, D-78224 SINGEN, W W W.ORBITALUM.COM, PHONE +49 (0) 77 31 792-0 131