No.
Error message
54
Shared folder could not be
created/connected
55
Touch screen could not be
changed
56
CAN timeout error
57
Required current higher than
the maximum current of the
inverter
58
Weld held parameters for
wire are incorrect.
9.4

Status LED indicators

There are three smaller LEDs lighting green or flashing on the rear of the machine:
1. Process (CPU alive)
2. Coolant pump on or off
3. Coolant flow
LED 1 does not light up
LED 2 does not light up
LED 3 does not light up
9.5

Temporarily deactivating sensors and monitoring functions

9.5.1

Sensors

Certain sensors can be deactivated temporarily. This can make sense, for example, when a defective gas sensor is present
and work is to continue. Greater attention is required when continuing work with the machine.
The sensors cannot be deactivated permanently: Deactivation of the sensors for gas and coolant monitoring is reset each
time the machine is switched off. The sensor is active again after the machine is started again.
9.5.2

Monitoring limits

The application of the monitoring limits can also be deactivated.
9.5.3

External input for aborting

If an external device with abort function is connected (for example residual oxygen meter), the function must be acti-
vated so that the abort signal is processed by the unit in the machine.
If an external device is not connected, the function must be deactivated.
X When deactivating sensors and monitoring limits, be aware that the corresponding monitoring function is no longer
active.
Example: With the gas sensor deactivated, the welding process is no longer interrupted if the gas bottle is empty.
X Deactivate sensors only in cases where this is absolutely necessary.
148
orbitalum tools GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
Explanation/Elimination
X Check whether the shared folder is set to "Public".
X Check whether the input data are correct.
X Check whether the IP address range matches.
X Restart the machine.
X Acknowledge the message with "Okay".
If the welding process is not possible:
X Contact the Orbitalum service.
X Check the current settings.
If this error message appears repeatedly:
X Contact the Orbitalum service.
X Check the wire settings.
> Machine off
> Coolant pump off
> Coolant flow does not exist
ORBIMAT 300 SW
(14.01.21) OW_ORBIMAT_300SW_BA_852060202_00_EN