2.

INFORMATION AND SAFETY INSTRUCTIONS

2.1

Requirements for the responsible body

Workshop/outdoor/field use: The responsible body is responsible for safety in the danger zone around the machine, and
should allow only qualified personnel to enter the zone or operate the machine in the danger zone.
Employee safety: The operator has to observe the safety regulations described in this chapter as well as has to work
safety-consciously and with all prescribed safety equipment.
The employer undertakes to give the employees clear notice of the dangers arising that are specified in the EMF direc-
tives and to evaluate the workplace correspondingly.
Requirements for special EMF evaluations with regard to general activities, working materials and workplaces*:
TYPE OF WORKING MATERIALS OR
WORKPLACE
Arc welding, manual (including MIG (Metal
Inert Gas), MAG (Metal Active Gas), TIG (Tung-
sten Inert Gas)) under observance of tried-
and-tested procedures and without physical
contact to the line
*
According to Directive 2013/35/EU
2.2

Using the machine

2.2.1

Proper use

The orbital welding power supply is intended solely for the following utilization:
Utilization in combination with an orbital weld head of the company Orbitalum Tools GmbH or with
a compatible third-part device in combination with a weld head adapter of the company Orbitalum
Tools GmbH.
TIG welding of materials that are specified in these operating instructions (see Kap. 4, Seite 94).
Empty unpressurized tubes that are free of contaminations, explosive atmospheres or liquids.
Intended use also includes the following points:
Permanent supervision of the machine during operation. The operator must always be able to stop the process.
Observing all safety instructions and warning messages in these operating instructions.
Observing of the further applicable documents.
Complying with all inspection and maintenance work.
Use of the machine solely in its original state.
Usage solely of original accessories as well as original spare parts and operating materials.
Usage solely of protective gases that are classified for TIG welding process in accordance with EN ISO 14175.
Usage solely of coolant OCL-30 of the company Orbitalum Tools GmbH.
Checking of all the safety-relevant items and functions before commissioning.
Processing of those materials named in the operating instructions.
82
orbitalum tools GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
EVALUATION REQUIRED FOR:
Employees without
Employees at particular
particular risk
risk (with the exception
of those with active im-
(1)
No
ORBIMAT 300 SW
Employees with active
implants
plants)
(2)
No
(14.01.21) OW_ORBIMAT_300SW_BA_852060202_00_EN
(3)
Yes