Example: 60 A is programmed for the high-pulse current in a sector. During the process, a value of 55 A (–5A) is mea-
sured: A warning message appears ("High-pulse current too low"). The process continues running. The operator can
carry out further measures (for example manual initiation of the current slope-off).
Maximum HP current alarm
Upward deviation of the high-pulse current (HP): If the specified deviation (5 A) is reached, a warning message appears.
Example: 60 A is programmed for the high-pulse current in a sector. During the process, a value of 65 A (+5A) is mea-
sured: A warning message appears ("High-pulse current too high"). The process continues running. The operator can
take further measures.
Maximum HP current abort
Upward deviation of the high-pulse current (HP): If the specified deviation (+10 A) is reached, welding is aborted.
Example: 60 A is programmed for the high-pulse current in a sector. During the process, a value of 70 A (+10A) is mea-
sured: The process is aborted. The gas post purge time is still observed.
This method of functioning applies for the following parameters in the same way:
Minimum/maximum LP current
Minimum/maximum HP speed
Minimum/maximum LP speed
Minimum/maximum voltage
The minimum and maximum deviations are not specified for the arc. The absolute voltage values are provided instead.
There is no setpoint value for the arc voltage in the procedure which can be compared to the current measured value.
Minimum/maximum voltage abort
Welding is aborted when the value is reached.
Minimum/maximum voltage alarm
A warning message appears when the value is reached.
8.10

Data documentation and data management

8.10.1

Managing data

Deleting data
1. In the main menu select the "Program Manager".
2. Press softkey 2 "Manage".
3. Use the rotary knob to mark either a folder or an individual log.
If a log/procedure is to be deleted from a further folder, the message "Cancel the selection" is displayed when the new
folder/file is selected.
X "Yes"
= Selection is cancelled. The check mark is removed at all the files previously marked.
X "No"
= Selection is retained.
Subsequently new files can be added to the selection.
4. Press the "Delete" button or softkey 3.
The text field "Really delete the selected directories and/or files?" is displayed.