2. Move the pointer to the 45° position with the rotary knob.
3. Briefly press the rotary knob.
The new sector border is set, and the sector list is updated. The new sector appears in the list.
The parameters of the new sector are copied from the previous sector.
4. Adjust parameters of the new sector.
Example: Delete sector 1
1. In the main menu, select "Manual/Adjust programming" > "Divide into levels".
The sector list appears on the left in the display (five sectors in the example, see Abb. 14). The process sequence ap-
pears on the right.
2. Move the pointer to the 90° position with the rotary knob.
3. Ensure that the pointer is positioned correctly. For this purpose, compare value in the sector list (end sector 1 =
90°) with the degree information.
4. Briefly press the rotary knob.
5. Move the pointer to the next-lowest border to the left (0°) with the rotary knob.
6. Briefly press the rotary knob.
Sectors 1 (0 - 90°) and 2 (90 - 185°) are combined to form a new sector 1 (0 - 185°). Sector 1 and the parameters of this
sector are deleted. The new sector has the parameters of the old sector 2.
7.
Check parameters of the sector.
Note: Moving the sector border to the right (185°) causes the new sector 1 to accept the parameters of the old sector 1.
8.4

Saving and calling up a procedure

8.4.1

Saving a procedure

Procedure status
With an unsaved procedure, "[unsaved]".appears next to the name of the procedure in the "Procedure name" field in the
display. The procedures are saved in folders. The folders can be created and named as desired. The "Default" folder is
specified and cannot be deleted.
X Recommendation: Save procedures regularly, including after adjusting individual parameters.
Saving a procedure under an existing name
The name of the folder in which the procedure is saved appears in the "Folder" field in the display.
1. Press softkey 3 ("Save").
A prompt appears.
2. Confirm the prompt with "Yes".
3. The procedure is saved with the adjustments.
Saving an adjusted procedure under a new name
1. Press the "Save" button in the main menu.
2. Press "New folder" button or select an existing folder.