ORBIMAT 300 SW
8.

OPERATION

8.1

Auto programming

8.1.1

Setting parameters

1. Connect the weld head.
2. Switch on the machine.
The main menu appears in the display.
3. Select and highlight the "Auto programming" menu item.
The following display appears:
Abb. 3:
Sub menu – Auto programming
8.1.2

Configuring weld head

1. Select the "Weld head" field and briefly press the rotary knob.
The following display appears:
Selecting a weld head
(14.01.21) OW_ORBIMAT_300SW_BA _852060202_00_EN
Field "....":
Return to main menu.
Fields "Weld head model" to "Wall thickness":
Parameter entry.
Field "Wire feed":
Welding with/without filler wire.
"Calculate program":
Calculation of the procedure with the entered parameters.
A list of the weld heads which can be used with this sys-
tem appears.
This system automatically detects the type of connected
head and offers it for selection first. In the example, this
is an DVR 50.