Special Keyboard Commands - Orbitalum ORBIMAT 300 SW Traduccion Del Manual De Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 309
EnGLISH
1. Save the procedures to be transferred at the initial machine onto a USB stick.
2. For OM 160 C, OM 250 C or OM 300 C: An adapter from PCMCIA to a medium which is readable by the card reader of
the CA machine (CF, SD, SM, MMC, Sony Memory Stick) is required.
If the procedures are saved on an external PC:
Z Transfer the procedures to a USB stick. Create a "PROGRAM" folder in the process.
This structure is required for identifying the procedures on the SW.
Z Copy the procedures to this folder.
Z Copy the folder to the top level of the USB stick.
3. Connect the USB stick.
The USB stick symbol is displayed at the bottom right in the display.
4. In the main menu, select "System settings" > "Service" > "Import procedures".
The folder structure of the machine appears in the display.
Z To create a new folder, select "New folder", enter a name and confirm.
5. Select the folder.
The data are transferred and converted in the internal memory of the machine. The original procedure names, com-
ments etc. are retained on the USB stick.
8.17

Special keyboard commands

The following commands can be entered on the external or virtual keyboard.
Alt + VER
Display the software version.
Alt + SER
Display the service screen.
Alt + SLO
Switches the slope representation from % (standard) to seconds.
136
orbitalum tools GmbH, D-78224 Singen, www.orbitalum.com, Phone +49 (0) 77 31 792-0
ORBIMAT 300 SW
(14.01.21) OW_ORBIMAT_300SW_BA_852060202_00_EN