ORBIMAT 300 SW
9.
SERVICE AND TROUBLESHOOTING
9.1
Performing service work
X In the main menu select "System settings" > "Service".
The following display appears:
Abb. 26:
Service menu
9.1.1
Pumping out coolant
Use when changing the coolant and emptying the tank in case of longer standstill of the cooling unit
1. Ensure that the cooling unit is properly connected to the power source.
2. Connect the drain hose on the flow connection (blue).
3. Lead drain hose into a suitable container to catch the coolant water.
4. Press the "Coolant pump on" button.
A message appears. The coolant is pumped out of the flow connection of the machine (blue) without the coolant sensor
in the return line being able to interrupt the process. To protect the pump against dry running, this process is limited in
time to approx. 30 seconds.
5. Select "Cancel" when the coolant is fully pumped out to avoid unnecessary dry running of the pump.
If the tank is not pumped empty:
X Start the process again.
9.1.2
Performing motor calibration
Use to check and correct the motor speed.
If several weld heads of the same type are used, a motor calibration should be carried out repeatedly before use.
If different weld head models are used, this is not required, as the machine saves a separate deviation for each head
model.
Continuously large and constantly different speed deviations are an indicator of a defect in the power source or weld
head that cannot be compensated via motor calibration.
1. Press the "Calibrate motor" button.
(14.01.21) OW_ORBIMAT_300SW_BA _852060202_00_EN
ORBITALUM TOOLS GMBH, D-78224 SINGEN, W W W.ORBITALUM.COM, PHONE +49 (0) 77 31 792-0 137