X People with heart problems or cardiac pacemakers may not operate the welding system.
X The operator has to ensure safe design of the workplace in accordance with the EMF Directive 2013/35/EU.
X Use only electrical devices with protective insulation in the working area of the welding system.
X Observe electromagnetically-sensitive devices when igniting the system.
2.7.9

Risk of suffocation through an excessive argon share in the air

DANGER!
If the argon share in the air rises above 50%, lasting damage or risk of death can arise suffocation.
X Ensure sufficient ventilation in rooms.
X If necessary, monitor the oxygen level in the air.
2.7.10

Health problems

WARNING!
Poisonous vapors and substances during the welding process and handling of the electrodes!
X Use extraction devices in accordance with the professional association regulations (e.g. BGI: 7006-1).
X Extra caution is required with chrome, nickel and manganese.
X Do not use electrodes containing thorium.
2.7.11

Danger of system tipping over

Manifold injuries and damage to property through system (for example ORBICAR welding carriage,
WARNING!
gas bottle, welding power supply, cooling unit) tipping over from the application of force from outside!
X Set up the machine so that it stands securely against external influences.
X Keep moving masses at least 1 meter away from the machine.
2.7.12

Danger of explosion and fire

Danger of explosion and fire through flammable materials near the welding zone or solvent in the
DANGER!
room air.
X Do not weld near solvents (for example where painting is being carried out) or explosive substances.
X Do not use flammable substances as a base in the welding area.
X Ensure that no flammable materials or soiling is located near the machine.
2.7.13

General injuries through tools

Injuries can occur during dismantling for the proper disposal of the orbital welding power supply
CAUTION!
through uncertainties in handling tools.
X In case of uncertainties send the orbital welding power supply to Orbitalum Tools – proper disposal is carried out