AVENTICS | CANopen | R412005742–BDL–001–AD
Assembly
Output-Modul
O0...O7
4
3
1
1
2
5
4
1. Wire the outputs according to Tab. 10 (DO8_M8) or Tab. 11
(DO8_M12).
2. Connect the electrical inputs/outputs to the I/O modules
with M8 or M12 coupling plugs (accessories).
3. To ensure the IP65 protection class, close unused sockets
with M8 or M12 protective caps (accessories).
Table 10:
Pin
1
4
3
Housing
Table 11:
Pin
1
3
2
3
4
5
Housing
Total current is too high
Every output is supplied with a continuous current of max.
0.5 A. Current loads over 0.5 A per output can lead to limited
system functioning.
Make sure that the current load of 0.5 A per output is not
O
exceeded.
Output assignment for 8x output module,
DO8_M8, M8x1 socket
Signal
Free
Ox
GND
Output assignment for 8x output module,
DO8_M12, M12x1 socket, A-coded
Signal
NC
O1, O3, O5 oder O7
GND
O0, O2, O4 oder O6
NC
NOTICE
Assignment
Not assigned
Ox output signal
(nominal voltage 24 V)
GND actuator reference
Connected to shield potential
Assignment
Not assigned
Output signal
Reference potential
Output signal
Not assigned
Connected to shield potential