Aventics CANopen Instrucciones De Servicio página 120

Ocultar thumbs Ver también para CANopen:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 325
120
AVENTICS | CANopen | R412005742–BDL–001–AD
Commissioning and operation
Table 17:
Examples for assignment of switches and valve supply, 32 valve solenoids
S4
0
A0.0
A0.1
A0.2
A0.3
A0.4
A0.5
A0.6
A0.7
S5
1
A1.0
A1.1
A1.2
A1.3
A1.4
A1.5
A1.6
A1.7
S6
2
A2.0
A2.1
A2.2
A2.3
A2.4
A2.5
A2.6
A2.7
3
A3.0
A3.1
A3.2
A3.3
A3.4
A3.5
A3.6
A3.7
1)
White fields indicate valve positions with bistable valves.
Fields highlighted in gray indicate valve positions with mono-stable valves.
Example 1
Valve
Solenoid
1)
position
LED
1
14
12
2
14
12
3
14
12
4
14
12
5
14
12
6
14
12
7
14
12
8
14
12
9
14
12
10
14
12
11
14
12
12
14
12
13
14
12
14
14
12
15
14
12
16
14
12
Example 2
Subbase for bistable valves
Valve
Solenoid
1)
position
LED
1
14
2
14
3
14
4
14
5
14
6
14
7
14
8
14
9
14
10
14
11
14
12
14
13
14
14
14
15
14
16
14
Example 3
Valve
1)
position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Solenoid
LED
14
12
14
12
14
12
14
12
14
12
14
14
14
14
14
12
14
12
14
14
14
12
14
12
14

Publicidad

Tabla de contenido
loading

Tabla de contenido