PO WE R
X10
2
1
3
4
AVENTICS | CANopen | R412005742–BDL–001–AD
6.3.6

Connecting the output module load supply

Each output module has its own M12 connection for the load
supply. Each of the 4 outputs are supplied via the load supply.
The U
and U
voltages are galvanically isolated.
Q 2
Q1
The connection for the output module load supply must meet
the following requirements:
Cable socket: M12×1, 4-pin, A-coded without center hole
W
(to ensure correct plug-in connection).
Cable cross-section: per wire > 0.5 mm
W
Length: Max. 20 m
W
1. Set up the correct pin assignment (see Tab. 12) on the plug
connections if you do not use pre-assembled wiring.
2. Connect the load supply using the M12 plug.
Table 12:
Voltage supply assignment for 8x output module, DO8,
M12x1, A-coded
Pin
X10
1
0V_U
Q2
2
24V_U
Q1
3
0V_U
Q1
4
24V_U
Q2
2
Assignment
GND reference for voltage supply 2
24 V supply voltage 1 for outputs O0 to O3
GND reference for voltage supply 1
24 V supply voltage 2 for outputs O4 to O7