Descargar Imprimir esta página

Honda BF40D Manual De Instrucciones página 84

Publicidad

b. INSPECTION
• THERMOSTAT
1) Immerse the thermostat in water.
1
2) Heat the water and observe the operation of the thermostat
2
as the water temperature increases. Measure the water
temperature when the thermostat starts to open.
3
• Do not let the thermometer or the thermostat touch the
container; this may cause a false reading.
4
Start opening
5
Fully open
6
3) Measure the lift height when the thermostat is fully open.
7
Lift height
8
c. INSTALLATION
1) Install the anode metal on the cylinder block and tighten the 6 x 18 mm screw securely.
9
2) Install a new water jacket cover gasket on the water jacket cover.
Install the water jacket cover, and tighten the seven 6 x 22 mm flange bolts to the specified torque.
10
TORQUE: 12 N . m (1.2 kgf . m, 9 lbf . ft)
11
3) Install the thermostat, a new thermostat cover gasket and the thermostat cover on the cylinder block, and tighten the
two 6 x 20 mm flange bolts to the specified torque.
12
TORQUE: 12 N . m (1.2 kgf . m, 9 lbf . ft)
13
14
15
16
17
18
6 x 22 (7)
19
12 N . m (1.2 kgf . m, 9lbf . ft)
20
[6]
WATER JACKET COVER
8-4
o
o
52
C (126
F)
o
o
60
C (140
F)
3.0 mm (0.12 in) or more
[2]
THERMOSTAT
COVER GASKET
[1]
THERMOSTAT
[7]
WATER JACKET
COVER GASKET
[5]
6 x 18 mm
SCREW
[4]
ANODE METAL
84
[1]
THERMOMETER
[2]
THERMOSTAT
6 x 20 (2)
12 N . m (1.2 kgf . m,
9 lbf . ft)
[3]
THERMOSTAT COVER

Publicidad